TESA

Innovative measuring equipment since 1941.

An alliance between Swiss Made and Innovation

TESA UPC

Reference

TESA UPC single template w/o computer
TESA UPC HP single template with computer
TESA UPC HP 1/2 template w/ocomputer
TESA UPC HP 1/2 template with computer
Close
Drag a column here...
Aucune référence associée à ce produit
TESA Design
SWISS MADE
Standard EN ISO 3650
Packaging Packed suitable for shipping
Certificate
of another type In-house calibration certificate for the version with greater accuracy or declaration of
conformity for the standard version. Temperature device with SCS certificate.
Identification number All instruments with the option for greater accuracy are delivered with serial numbers
Execution Comparative measurement procedure with transference of the length of a reference gauge block to the gauge block being measured. Measuring configuration 2 probes connected in sum measurement (function +A+B) with mechanical contact with the measuring face. Measuring points On the reference gauge block: at the centre of the
measuring face (point R). On the gauge block to be measured: at the centre (point 1) as well as the 4 corners of the measuring face, each lying 2 mm away from the adjacent faces (points 2 to 5). Central length lc is defined by probing both points R and 1. Establishing lengths at any point requires measurements to be taken at points R plus 1 to 5. Variation in length v is the result of meas ure ments taken at points 1 to 5.
Mass ≈ 23 kg (comparator complete, but without computer). ≈ 4 kg (temperature device)
Application range For gauge blocks ranging from 0,5 mm to 100 mm or 0.02 in to 4 in

TESA UPC Gauge Block Comparator for Comparative Measurement
• Measures gauge blocks of same nominal length by comparison. 
• Comes with the new template system for positioning the gauge blocks. – Single or dual template system for optimum ease of gauge handling.
• Features TESA high-precision inductive probes.
• Allows ultra-precise temperature measurement, integrated.
• Transfers on-line all measured length and temperature values.
• Executes computer-aided data processing with all required correction values included.
• Performs calibrations that meet the requirements of both ISO standards and EA guidelines (EAL – European cooperation for Accreditation of Laboratories).
• Includes an execution for greater accuracy along with a calibration

certificate (optional).

Single Template System:
• With this system, your reference gauge blocks along with those to be calibrated    are moved together during the measurement cycles. TESA dual template   system (patented)
• Simultaneous use of two templates allows you to rest up your reference gauges until they are needed.
 

 

 

 

TESA Design
SWISS MADE
Standard EN ISO 3650
Packaging Packed suitable for shipping
Certificate
of another type In-house calibration certificate for the version with greater accuracy or declaration of
conformity for the standard version. Temperature device with SCS certificate.
Identification number All instruments with the option for greater accuracy are delivered with serial numbers
Execution Comparative measurement procedure with transference of the length of a reference gauge block to the gauge block being measured. Measuring configuration 2 probes connected in sum measurement (function +A+B) with mechanical contact with the measuring face. Measuring points On the reference gauge block: at the centre of the
measuring face (point R). On the gauge block to be measured: at the centre (point 1) as well as the 4 corners of the measuring face, each lying 2 mm away from the adjacent faces (points 2 to 5). Central length lc is defined by probing both points R and 1. Establishing lengths at any point requires measurements to be taken at points R plus 1 to 5. Variation in length v is the result of meas ure ments taken at points 1 to 5.
Mass ≈ 23 kg (comparator complete, but without computer). ≈ 4 kg (temperature device)
Application range For gauge blocks ranging from 0,5 mm to 100 mm or 0.02 in to 4 in

TESA UPC Gauge Block Comparator for Comparative Measurement
• Measures gauge blocks of same nominal length by comparison. 
• Comes with the new template system for positioning the gauge blocks. – Single or dual template system for optimum ease of gauge handling.
• Features TESA high-precision inductive probes.
• Allows ultra-precise temperature measurement, integrated.
• Transfers on-line all measured length and temperature values.
• Executes computer-aided data processing with all required correction values included.
• Performs calibrations that meet the requirements of both ISO standards and EA guidelines (EAL – European cooperation for Accreditation of Laboratories).
• Includes an execution for greater accuracy along with a calibration

certificate (optional).

Single Template System:
• With this system, your reference gauge blocks along with those to be calibrated    are moved together during the measurement cycles. TESA dual template   system (patented)
• Simultaneous use of two templates allows you to rest up your reference gauges until they are needed.
 

 

 

 

Complementary Products